Description
PLC Splitter is responsible to distribute optical signals from Central Office (CO) to multiple premise locations.We provides whole series of 1*N and 2*N splitter products that are tailored for specific applications. All prodcts meet GR-1209-CORE-2001 and GR-1221-CORE-1999 requirements.
Specification:
Performance Specifications: |
|||||||
1×N PLC Splitter (Measured at room temperature include connector data) |
|
|
|||||
TYPE |
1*2 |
1*4 |
1*8 |
1*16 |
1*32 |
1*64 |
|
Fiber Type |
G657A or customer Request |
||||||
Operating Wavelength(nm) |
1260~1650 nm |
||||||
Insertion Loss(dB) |
Max (include connector) |
4.2 |
7.5 |
11 |
14 |
17.4 |
20.5 |
Max(no connector) |
3.7 |
7.2 |
10.5 |
13.2 |
16.9 |
19.5 |
|
Uniformity Loss(dB) |
Max |
0.6 |
0.6 |
0.8 |
1.2 |
1.5 |
1.8 |
Polariation Dependent Loss(dB) |
Max |
0.2 |
0.2 |
0.2 |
0.3 |
0.3 |
0.5 |
Return Loss (dB) |
UPC:50 APC:55 |
||||||
Operating Temperature (°C) |
-40~+85 |
2×N PLC Splitter (Measured at room temperature include connector data) |
|
|
|||||
TYPE |
2*2 |
2*4 |
2*8 |
2*16 |
2*32 |
2*64 |
|
Fiber Type |
G657A or customer Reques |
||||||
Operating Wavelength(nm) |
1260~1650nm |
||||||
Insertion Loss(dB) |
Max(include connector) |
4.4 |
7.8 |
10.9 |
14.3 |
17.2 |
20.5 |
Uniformity Loss(dB) |
Max |
0.4 |
0.8 |
0.8 |
1 |
1.5 |
1.8 |
Polariation Dependent loss(dB) |
Max |
0.2 |
0.2 |
0.2 |
0.3 |
0.3 |
0.4 |
Return Loss (dB) |
UPC:50 APC:55 |
||||||
Operating Temperature (°C) |
-40~+85 |
||||||
Note:Connector type:SC,FC,LC,ST,etc, PC,UPC,APC are be ok.as request. |
PLC MINI TYPE AS STRUCTION PICTURE |
|||||||||
ORDER INFORMATION |
|||||||||
Wavelength (nm) |
Port |
Input Fiber Length |
Output Fiber Length |
Input Fiber Type |
Output Fiber Type |
Fiber Standard |
Input Connector |
Output Connector |
|
PLC=1260-1650 |
102=1*2 104=1*4 108=1*8 116=1*16 132=1*32 164=1*64 202=2*2 204=2*4 208=2*8 216=2*16 232=2*32 264=2*64 |
1=1M 2=2M 3=Customized |
1=1M 2=2M 3=Customized |
1=250um bare fiber 2=900um loose tube 3=900um tight tube |
1=250um bare fiber 2=250um ribbon fiber |
1=G652 2=G657A 3=G657B |
0=None 1=FC/APC 2=FC/PC 3=SC/APC 4=SC/PC 5=LC/PC 6=ST |
0=None 1=FC/APC 2=FC/PC 3=SC/APC 4=SC/PC 5=LC/PC 6=ST |
Application:
→ Measuring System and Laser System
→ DWDM and CWDM Systems
Feature:
- Low Excess loss
- Low PDL
- Full fiber core structure
- High channel counts
- Environmentally stable